CN | EN
Optical Reflective Film Thickness Gauge FILMTHICK-C50 Mapping

Optical Reflective Film Thickness Gauge FILMTHICK-C50 Mapping

 

 

Mapping Measurement and Mapping Series

Optical Reflective Film Thickness Meter · Wafer-level Full-Wafer Mapping

Wafer-level mapping for circular surveying, 380-1100nm spectral interferometry, 15nm to 70μm non-contact thickness measurement, fully compatible with 2 to 12 inches

 

Product Introduction

The FILMTHICK-C50-Mapping is a wafer-level Mapping measurement device designed for the semiconductor wafer, flat panel display, and precision optical coating industries. Based on the FILMTHICK-C series interferometric film thickness measurement platform, it integrates the R-Theta polar coordinate automatic movement platform, vacuum adsorption wafer stage, and dedicated Mapping measurement and mapping software. The device adopts the principle of reflective spectral interferometric thickness measurement, with a mechanical structure integrating imported long-life halogen tungsten lamp light sources. Combined with a self-developed high-precision spectrometer and three major inversion algorithms—FFT Fourier method, extreme value method, and fitting method—it achieves non-contact, non-destructive, high-precision measurement of wafers from 2 to 12 inches. It covers parameters such as single-layer and multilayer film thickness, refractive index n, extinction coefficient k, reflectivity, and color, and outputs full-sample two-dimensional and three-dimensional film thickness distribution maps.

The OPTICAFILMTEST optical film thickness measurement software features a rich and open material refractive index database, which can display interference, FFT spectra, and film thickness trends in real time during measurement, assisting users in testing and analysis. The hardware adopts a modular design, with core components that can be independently replaced, facilitating subsequent functional expansion. 

 

Core selling points

Wafer-level full-chip mapping: R-Theta polar coordinate automatic platform carries samples for radial and rotational degrees of freedom movement, with the optical system stationary and no assembly consistency differences between points; Automatically generates 2D contour cloud maps, 3D three-dimensional distribution maps, and profile lines; 

 

Fast: single-point measurement time less than 0.5 seconds; 5 points / 5 seconds, 25 points / 14 seconds, 57 points / 30 seconds, significantly reducing detection cycles; 

 

Wide range and high precision: single unit covers 15nm to 70μm, repeatability 0.2nm, stability better than 0.05nm, reducing equipment input and sample switching time; 

 

Full specifications from 2 to 12 inches: 2 / 4 / 6 / 8 / 12 inch wafers can be placed directly on the chip, no need to purchase separate chucks by size; 

 

Six types of scanning paths: circles and concentric circles / rectangles and squares / radial / center or edge removal / 4 fixed points / user-defined, also supports point programming and D distribution;

 

Measurement and simulation integrated: In addition to thickness inversion, it simultaneously provides refractive index n, extinction coefficient k, reflectance, and color; The built-in reflectance simulation module can assist in the development of new film process layers. 

 

Core Technical Parameters (Standard Configuration Indicators)

Product Model

FILMTHICK-C50-Mapping

Optical Principle

Reflective Spectral Interferometry (White Light Interference), Non-contact, Non-destructive Measurement

Spectral Range

380nm - 1100nm (Visible to Near-Infrared)

Light Source

Mechanically integrated imported long-life halogen tungsten lamp light source, lifespan over 3000 hours

Measurement Spot Size

1.5mm (Standard configuration, optional according to sample requirements)

Film Thickness Measurement Range

15nm - 70μm

Film Thickness Repeatability Accuracy

0.2nm (Maximum value from 100 measurements on 100nm SiO₂/Si standard sample)

Film Thickness Absolute Accuracy

0.2% or 2nm (whichever is larger)

Film Thickness Stability

Better than 0.05nm

Measurable Parameters

Film thickness d, reflectance spectrum R(λ), color, refractive index n, extinction coefficient k

Reflectance Simulation

Supports modeling of different film layer structures and simulation of coating system reflectance curves

Algorithm Model

FFT Fourier method, extremum method, curve fitting method, supporting multi-layer film layer-by-layer fitting

Single Point Measurement Time

Less than 0.5 seconds

Mapping Scan Speed

5 points / 5 seconds; 25 points / 14 seconds; 57 points / 30 seconds

Sample Stage Type

R-Theta polar coordinate automatic moving stage (radial and rotational dual degrees of freedom)

Travel Range

Not less than 200mm × 200mm, extendable to 300mm × 300mm

Supported Sample Size

2-inch / 4-inch / 6-inch / 8-inch / 12-inch wafers

Manual Operation Movement Repeatability

±0.2mm (Maximum value from 100 measurements on 100nm SiO₂/Si sample)

Supported Scanning Paths

Circular / rectangular / square / radial / central or edge removal / 4-point / user-defined

Software

OPTICAFILMTEST Optical Film Thickness Measurement Software (Mapping Wafer Measurement Version), Windows 10 / 11 64-bit; built-in open refractive index material database

User Permissions

Manager / Operator / Controller three-level permission management

Data Export

CSV / Excel / XML and 2D, 3D graphical files

System Integration

Supports interfacing with upper-level MES / SPC systems (interfaces open according to projects)

Operating Environment

Temperature 18-28°C, humidity <80% without condensation; AC 220V±10%, 50Hz

 

 

Model

UV

UVX

Basic model

NIRX

NIR

Wavelength Range

190-1100nm

190-1700nm

380-1100nm

380-1700nm

950-1700nm

Light Source

Deuterium lamp, Halogen tungsten lamp

Halogen tungsten lamp

Thickness Range

1nm-40um

1nm-250um

10nm-100um

10um-250um

100um-250um

Accuracy

0.02nm

0.02nm

0.02nm

0.02nm

0.1nm

*The final right of interpretation of this technical specification belongs to the manufacturer.

 

Applicable Industries and Application Scenarios

Semiconductor Wafer Coating Uniformity

Flat Panel Display (FPD)

Precision Optical Coating

New Energy and Photovoltaics

Life Sciences and Biomedical

Micro-LED and Optical Communication

 

Typical Measured Film Data

Samples and Coatings

Measured Thickness

Application Areas

SiO₂ (Silicon Dioxide)

2108nm

Optical Coatings and Passivation Layers

ITO (Indium Tin Oxide)

36nm

Touch Screens and Smart Windows

Parylene

2490nm

Protective Layers for Medical Implants

Microlens Coating

3012nm

Optical Components

*The above accuracy indicators were measured on standard 100nm SiO₂/Si samples under room temperature conditions of 23±2℃. The actual measurement data comes from records of the FILMTHICK-C series on real customer samples, and the feasibility of measurements on specific samples is subject to the results of sample submission and actual measurement.

 

Branch Models (Same platform, branched according to sample type)  

Branch models of FILMTHICK-C50-XY C50-Mapping  

Designed for square and non-standard substrate samples. It uses an XY rectangular coordinate positioning displacement platform, allowing point collection and index editing or import in Cartesian coordinates, to acquire spectra point by point and invert the thickness. It is suitable for scenarios focusing only on a few designated inspection locations, as well as point measurements of rectangular, strip-shaped, or irregular substrates.

Wavelength Range

380nm - 1700nm (VIS and NIR dual detectors, seamless data stitching)

Film Thickness Measurement Range

10μm - 250μm (conventional coatings, medium to thick films preferred)

Film Thickness Repeatability

≤0.02nm

Film Thickness Absolute Accuracy

≤0.2% or 2nm (whichever is greater)

Platform Type

XY right-angle coordinate dual-axis precision motion platform (servo, ball screw, grating ruler closed-loop)

Effective Travel

300mm × 300mm, expandable to 400mm × 400mm

Positioning Accuracy

≤ ±5μm

Repeat Positioning Accuracy

≤ ±2μm

Minimum Step Size

1μm

Movement Speed

0 - 200mm/s

Point Capacity

Single recipe supports over 200 points

Point Arrangement

Matrix automatic generation / manual coordinate input / mouse click selection / CSV and Excel point table import

Overall Machine Configuration

Floor-standing integrated steel cabinet, approximately 600mm × 750mm × 1500mm

Safety Configuration

Front door observation window, door safety interlock, emergency stop button, compliant with IEC 60825-1

*The final right of interpretation of this technical specification belongs to the manufacturer.

 

Standard Configuration

Host (including self-developed high-precision spectrometer and optical path)

1 unit

Imported long-life halogen-tungsten lamp light source

1 set

Measurement software (pre-installed license, three-level permission management)

1 set

SiO₂/Si standard calibration samples

1 set

Chinese operation manual, software manual, and calibration certificate

1 set

Common tool kit and spare consumables

1 set

Remote diagnosis and online upgrade module

1 set

Transport packaging box

1 set

 

 

Service Commitment

Installation and Training

Provide online remote training and on-site installation services; after installation, operation training is conducted, covering instrument operation, software usage, measurement methods, and data analysis.  

Warranty Period

One-year free warranty from the date of purchase; quality issues within the warranty period are repaired free of charge and faulty components are replaced; lifetime maintenance at cost price is provided after the warranty period.

Response Time

Response within 8 working hours on weekdays; first response within 4 hours in emergencies.  

On-site Service Time

On-site service within 24 hours in Guangzhou and surrounding areas, within 48 hours in South China, and within 72 hours in major provincial capitals nationwide.

Spare Parts Support

Provide solutions for faulty components within 7 working days; commonly used consumables and vulnerable parts are stocked locally.  

Calibration and Measurement

Provide national metrology institute or third-party traceable calibration certificates (CNAS optional).  

Sample Testing

Before contract signing, free sample testing can be arranged, with actual measurement evaluation coefficients and repeatability data provided.  

Software Upgrade

Free upgrades within the instrument’s service life (same model); remote diagnostics and online upgrade modules are provided.

 

 

Why Choose Jingyi Optoelectronics?

Independent R&D

The film thickness inversion algorithms (FFT Fourier method, extremum method, curve fitting method) and the OPTICAFILMTEST measurement software are all independently developed by our company; the spectral acquisition module uses a self-developed high-precision spectrometer.

 

National High-Tech Enterprise

Founded in 2013, our company is recognized as a National High-Tech Enterprise, a specialized and innovative enterprise, and a 'Little Giant' enterprise in technological innovation; we maintain long-term collaborations with universities and research institutes such as Tsinghua University and Peking University.

 

Localized Service

Our Guangzhou headquarters provides direct service nationwide, offering online remote training, on-site installation, remote fault diagnosis, and rapid spare parts delivery; the service chain is shorter compared to the indirect models of imported brands through agents.

 

Sample Testing Verification

Before signing a contract, we can arrange free sample testing, providing actual measurement evaluation coefficients and repeatability data as a basis for configuration confirmation and acceptance.

 

Consult customer service to obtain detailed materials and exclusive solutions.

Tel: 400-1800-685

Email:info@gzjygd.com